Local Storage seems to be disabled in your browser.
For the best experience on our site, be sure to turn on Local Storage in your browser.
ETA K 1200 F WOJR
ETA K...F |
ETA K 1200 F WOJR | 134275


8.669,30 €
Lieferzeit auf Anfrage
- Ausführung rechts
- Regelung integriert, steckerfertig verdrahtet
- Automatischer Sommerbypass
- Erhitzer PWW
- Paneelfilter F7/M5
- Volumenkonstante EC Ventilatoren
ETA K 1200 F WOJR | 50 Hz | |
Spannung UN | 230 V 1~ |
Strom Imax | 4 A |
Fördermitteltemperatur tM | 40 °C |
Drehzahlsteuerung | 0-10V |
Motorschutz | TEC |
Anschlussleistung P | 587 W |
IP Schutzart Komplettgerät | IPX4 |
Gewicht | 192,0 kg |
Isolationsklasse Motor | F |
Polzahl | - |
IP Schutzart Motor | IP30 |
IP Schutzart Klemmkasten | - |
IP Schutzart Komplettgerät | IPX4 |
Min. Einsatztemperatur | -30 °C |
Σ-Schallleistung (LW) dB(A) | |||
---|---|---|---|
Zuluft | Abluft | ||
Ansaug | ∑LWA5 |
-
|
-
|
Ausblas | ∑LWA6 |
-
|
-
|
Abstrahl | ∑LWA2 |
-
|
-
|
WRG | ||
---|---|---|
Temp. Zuluft |
-
|
℃ |
Leistung |
-
|
kW |
Wirkungsgrad |
-
|
% |
Druckverlust Luft |
-
|
Pa |
Heizen | ||
---|---|---|
Temp. Zuluft |
-
|
℃ |
Leistung |
-
|
kW |
Leistung max. |
-
|
kW |
Druckverlust Luft |
-
|
Pa |
Wassermenge |
-
|
m³/h |
Druckverlust Wasser |
-
|
kPa |
Anschluss |
-
|
" |
Typ ETA K 1200 F WOJR
ID 134275
ID 134275
Anschlussdaten des Gesamtgerätes | ||
Nennfrequenz | Hz | 50 |
Nennspannung | V | 230 |
Nennleistungsaufnahme | W | 587 |
Max. Betriebsstrom | A | 4 |
Phasen | 1~ | |
Motortyp | EC | |
Steuerart Motor | 0-10V | |
Motorschutz | TEC | |
Kondensatorkapazität | µF | - |
Kondensatorspannung | V | - |
Isolationsklasse Motor | F | |
Polzahl | - | |
IP Schutzart Motor | IP30 | |
IP Schutzart Klemmkasten | - | |
IP Schutzart Komplettgerät | IPX4 | |
Min. Einsatztemperatur | °C | -30 |
Gewicht | kg | 192,0 |
Aussenluft - Zuluft | Abluft - Fortluft | ||
Nennstrom | A | 1.9 | 1.9 |
Nenndrehzahl | 1/min | 3060 | 3060 |
Max. stat. Wirkungsgrad | % | 37.9 | 37.9 |
Max. tot. Wirkungsgrad | % | 37.9 | 37.9 |
Max. zulässige Frequenz (bei 3˜ Motoren) | Hz | - | - |
Max. zulässige Drehzahl (bei EC-Motoren) | 1/min | - | - |
Max. Leistungsaufnahme | W | 284 | 284 |
Max. Stromaufnahme | A | 2 | 2 |
Max. Drehzahl | 1/min | 3340 | 3340 |
Max. Fördervolumen | m³/h | 1375 | 1375 |
Min. Druck | Pa | - | - |
Max. Druck | Pa | 815 | 815 |
Max. zulässige Umgebungstemperatur bei Nenn | °C | 40 | 40 |
Max. zulässige Fördermitteltemperatur bei Nenn | °C | 40 | 40 |
Max. zulässige Umgebungstemperatur | °C | 40 | 40 |
Max. zulässige Fördermitteltemperatur | °C | 40 | 40 |
Blockierstrom | A | - | - |
Min. zulässige Spannung | V | 230 | 230 |
Aussenluft - Zuluft
Geräuschmessung (Oktaven) | ∑ | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1k Hz | 2k Hz | 4k Hz | 8k Hz | |||
Schallleistg. Ansaug | LWA5 | dB(A) | 2 | 77 | 53.1 | 66.1 | 71.1 | 71.3 | 71.7 | 66.0 | 65.1 | 57.0 |
3 | 74 | 44.1 | 56.4 | 66.6 | 67.8 | 69.5 | 64.7 | 63.9 | 56.2 | |||
4 | 76 | 44.1 | 58.0 | 68.0 | 69.6 | 72.3 | 66.9 | 64.8 | 54.9 | |||
5 | 79 | 44.8 | 60.8 | 70.4 | 73.4 | 75.9 | 69.8 | 67.0 | 56.6 | |||
Schallleistg. Ausblas | LWA6 | dB(A) | 2 | 69 | 53.1 | 56.7 | 60.5 | 61.9 | 64.5 | 59.4 | 52.4 | 41.8 |
3 | 64 | 48.6 | 44.9 | 52.4 | 55.6 | 61.4 | 55.9 | 49.9 | 38.3 | |||
4 | 66 | 47.6 | 46.9 | 55.0 | 57.8 | 63.1 | 58.3 | 50.7 | 36.3 | |||
5 | 69 | 45.4 | 50.1 | 57.8 | 61.5 | 66.5 | 61.5 | 53.4 | 38.5 |
Abluft - Fortluft
Geräuschmessung (Oktaven) | ∑ | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1k Hz | 2k Hz | 4k Hz | 8k Hz | |||
Schallleistg. Ansaug | LWA5 | dB(A) | 2 | 64 | 50.9 | 51.4 | 55.9 | 59.5 | 58.1 | 53.3 | 52.0 | 49.8 |
3 | 66 | 56.9 | 46.2 | 55.3 | 60.2 | 61.0 | 59.1 | 53.2 | 46.7 | |||
4 | 68 | 52.7 | 48.3 | 57.9 | 63.8 | 62.9 | 56.4 | 48.9 | 44.0 | |||
5 | 70 | 44.3 | 50.5 | 59.7 | 66.6 | 65.3 | 58.2 | 50.2 | 44.9 | |||
Schallleistg. Ausblas | LWA6 | dB(A) | 2 | 84 | 55.5 | 65.3 | 71.5 | 75.3 | 78.9 | 77.4 | 74.3 | 70.0 |
3 | 84 | 51.5 | 58.5 | 71.5 | 75.7 | 81.2 | 76.9 | 73.8 | 69.0 | |||
4 | 86 | 51.4 | 62.2 | 74.9 | 79.5 | 81.7 | 80.4 | 76.1 | 71.6 | |||
5 | 88 | 48.4 | 64.1 | 76.3 | 81.1 | 83.5 | 82.3 | 77.6 | 72.7 |
Geräuschmessung (Oktaven) | ∑ | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1k Hz | 2k Hz | 4k Hz | 8k Hz | |||
Schallleistg. Abstrahl | LWA2 | dB(A) | 2 | 62 | 53 | 56 | 57 | 52 | 51 | 47 | 45 | 41 |
3 | 58 | 51 | 44 | 51 | 48 | 55 | 47 | 45 | 36 | |||
4 | 59 | 49 | 46 | 53 | 51 | 55 | 45 | 38 | 30 | |||
5 | 61 | 48 | 49 | 55 | 56 | 54 | 46 | 39 | 31 |
Daten gemäß ErP Richtlinie laut EU-Verordnung 327/2011 | ||
Gesamteffizienz | % |
54.6
|
Messkategorie |
A
|
|
Effizienzkategorie |
statisch
|
|
Effizienzgrad am Energieeffizienzoptimum | N |
70.8
|
Drehzahlregelung |
integriert
|
|
Herstellungsjahr |
siehe Typenschild
|
|
Amtliche Registriernummer |
Amtsgericht Mannheim HRB 560366
|
|
Niederlassungsort des Herstellers |
ruck Ventilatoren GmbH, Deutschland
|
|
ID-Nummer |
134275
|
|
Nennmotoreingangsleistung am Energieeffizienzoptimum | kW |
0.284
|
Volumenstrom am Energieeffizienzoptimum | m³/h |
915
|
Druck am Energieeffizienzoptimum | Pa |
573
|
Umdrehung pro Minute am Energieeffizienzoptimum | 1/min |
3042
|
Spezifisches Verhältnis |
Spezifisches Verhältnis liegt nahe bei 1 und deutlich unter 1,11.
|
|
Informationen zur Demontage, Recycling und Entsorgung |
Bitte beachten Sie die Bedienungsanleitung des Produktes.
|
|
Optimale Lebensdauer |
Bitte beachten Sie die Bedienungsanleitung des Produktes.
|
|
Beschreibung weiterer bei der Ermittlung der Energieeffizienz von Ventilatoren genutzter Gegenstände wie Rohrleitungen, die nicht in der Messkategorie beschrieben und nicht mit dem Ventilator geliefert werden. |
Für die Ermittlung der Energieeffizienz wurden keine besonderen Gegenstände außer den gemäß der Messkategorie verlangten Anschlusskomponenten eingesetzt.
|
SEN CO2-OPTION
SEN RH
SEN RAUCH 02
SEN RAUCH 01
SEN TEMP
STK 05